Alfa Laval SB Pressure Relief Valve
The Pressure Relief Valve is used for minimizing the risk of damage to tanks due to liquid overfilling.

Product Description

Working Principle

The Pressure Relief Valve is delivered with counter weight set and locked to suit customer requirements regarding opening pressure. When pressure in the tank exceeds the preset opening value, the valve relieves the excess pressure.

Standard Design

The Pressure Relief Valve is available in two versions:

  •  Integrated in a SCANDI BREW® tank top system
  •  Mounted on its own welding flange

Compliance to EN 4126-1
Compliance to EN 764-7
Compliance Pressure Equipment Directive 2014/68/EU of the European Community, Fluida Group II

The advantages of an integrated Pressure Relief Valve are lower initial costs, superior hygiene and smaller area required for the valve. The size and setting of the Pressure Relief Valve is based on the tank design data and process requirements.

Technical Data

Nominal size                             Set Pressure Range
75mm. . . . . . . . . . . . . . . . . . . . . . 0.2 – 3.5 bar
100mm . . . . . . . . . . . . . . . . . . . . 0.2 – 2.5 bar
150mm . . . . . . . . . . . . . . . . . . . . 0.4 – 1.5 bar

Physical Data

Materials

Product wetted steel parts: . . .EN 1.4404 (AISI 316L) with 3.1 cert.
Product wetted steel surfaces: .Surface roughness Ra<0.8 μm
Product wetted seals: . . . . . .EPDM

Cleaning In Place (CIP)

The Pressure Relief Valve is cleaned in closed position by the tank cleaning head, but this will not include the valve seating. To include the valve seating in the cleaning cycle, there is the option to equip the valve with a pneum. force opener and a splash guard.

Integrated Valve                                                                                                         Options

 

Options:
Pos. 1: Force opener: force opening during cleaning cycle
Pos. 2: Splash guard: containing CIP liquid during valve seat cleaning
Pos. 3: Proximity sensor: for operation detection
Pos. 4: Welding flange: for installation

Flange Mounted Valve

Interface requirements (mm)

Discharge Capacity

In accordance with EN 4126-1
Capacity measured at:
∆P=10% Set pressure ≥ 1 bar
∆P=0,1 Set pressure < 1 bar
Medium: water (20°C)